MSHA Salvador: 3.5 HP - 3"
Based on the same basic design as the drainage pumps, the sludge pumps come into action when the liquid gets dirtier than can be handled by the drainage pumps. The design even permits converting between drainage and sludge models allowing you to adapt the pump according to the varying conditions.
Technical data
Pump type:
Electrical submersible
Three-phase
Classification:
Class IP 68
Maximum submersion: 66 ft
Standard Power Cable:
SUBCAB:
3-phase: 50 ft: 14AWG/7
Other cable sizes and lengths available.
Contact Grindex.
Discharge:
3" - hose, ISO-G or NPT
Limitations:
pH 5-8
Maximum liquid temperature: 104°F
| 60 Hz |
|
Salvador 3-phase |
| Rated power P2 |
|
3.5 HP |
| Maximum absorbed power P1 |
|
2.6 kW |
| Rated current at 230V |
|
|
| Rated current at 460V |
|
4.7 A |
| Rated current at 575V |
|
3.6 A |
| Shaft speed |
|
3410 r.p.m. |
| Throughlet / Maximum solid size |
|
Ø 2" |
| Weight |
|
75 lbs |
| Dimensions (max width / height) |
|
14.8" / 30.1" |